Studio-technologies 55 2005 Manual do Utilizador Página 33

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 32
Model 55/56 User Guide Issue 5, August 2005
Studio Technologies, Inc. Page 33
Function: Control Room Level
Byte Value Description
1 F0H System-Exclusive Message
2 00H 1st Byte of Studio Tech ID
3 00H 2nd Byte of Studio Tech ID
4 56H 3rd Byte of Studio Tech ID
5 02H Product ID (Model 55)
6 07H Function: Control Room Level
7 0nH Level, MSB, range 0-3, see notes
8 nnH Level, LSB, range 00-7F, see notes
9 F7H EOX, End of System Exclusive
Notes:
MSB=0 allows LSB to control lower 128 level steps, MSB=1 allows LSB eld to control upper 128
level steps. During operation MSB=0/LSB=00 gives minimum output level (maximum attenuation),
MSB=1/LSB=7F gives maximum output level.
MSB=2 places function in reduced precision mode, where LSB=00 gives minimum output level (maximum
attenuation), LSB=7F is maximum output.
MSB=3 places function in reduced precision, reverse range mode, where LSB=7F gives minimum output
level (maximum attenuation), LSB=00 is maximum output.
Function: Control Room Output Select
Byte Value Description
1 F0H System-Exclusive Message
2 00H 1st Byte of Studio Tech ID
3 00H 2nd Byte of Studio Tech ID
4 56H 3rd Byte of Studio Tech ID
5 02H Product ID (Model 55)
6 09H Function: Control Room Output Select
7 nnH Output Selected, Range 00-11:
L Ch. R Ch. Action
0 0 No Output
1 0 Left Only
0 1 Right Only
1 1 Left and Right
8 F7H EOX, End of System Exclusive
Function: Control Room Mono/Stereo Select
Byte Value Description
1 F0H System-Exclusive Message
2 00H 1st Byte of Studio Tech ID
3 00H 2nd Byte of Studio Tech ID
4 56H 3rd Byte of Studio Tech ID
5 02H Product ID (Model 55)
6 0AH Function: Control Room Mono
7 0nH Output Selected, Range 0-1, 0=stereo, 1=mono
8 F7H EOX, End of System Exclusive
Vista de página 32
1 2 ... 28 29 30 31 32 33 34 35 36 37 38 39 40 41

Comentários a estes Manuais

Sem comentários