Issue 4, June 2002 Model 55/56 User Guide
Page 40 Studio Technologies, Inc.
Function: Set Dim Level
Byte Value Description
1 F0H System-Exclusive Message
2 00H 1st Byte of Studio Tech ID
3 00H 2nd Byte of Studio Tech ID
4 56H 3rd Byte of Studio Tech ID
5 02H Product ID (Model 55)
6 10H Function: Set Dim Level
7 0nH Status, Range 0-5:
0=full mute (approx. 70dB)
1=30dB dim
2=25dB dim
3=20dB dim
4=15dB dim
5=10dB dim
8 F7H EOX, End of System Exclusive
Function: Control Room Mute
Byte Value Description
1 F0H System-Exclusive Message
2 00H 1st Byte of Studio Tech ID
3 00H 2nd Byte of Studio Tech ID
4 56H 3rd Byte of Studio Tech ID
5 02H Product ID (Model 55)
6 11H Function: Control Room Mute
7 0nH Status, Range 0-1, 0=No Mute, 1=Mute
8 F7H EOX, End of System Exclusive